Click to enlargeAltronix AL600ULACM UL Listed Power Supply/Charger <br>w/Multi-Output Access Power Controller

Overview
Altronix AL600ULACM converts a 115VAC 60Hz input into eight (8) independently controlled 12VDC or 24VDC non power limited fuse protected Fail-Safe and/or Fail-Secure outputs with a total of 6 amp continuous supply current. The fire alarm disconnect feature enables emergency egress in the event the fire alarm system is activated. It is individually selectable for any or all of the eight (8) outputs. Model AL600ULACMCB is a PTC protected version of this unit.

Agency Listings
  • UL Listed for Access Control Systems (UL294)
  • CUL Listed - CSA Standard C22.2 No.205-M1983, Signal Equipment File# BP6714.
  • CSFM - California State Fire Marshal Approved. File # 7315-1335:106.
  • MEA - NYC Department of Buildings Approved.

    Features/Specifications
    Power Supply/Charger:
  • 12VDC or 24VDC selectable output.
  • 6 amp of continuous supply current.
  • 115VAC 60Hz, 1.9 amp input.
  • Filtered and electronically regulated outputs.
  • Short circuit and thermal overload protection.
  • Built-in charger for sealed lead acid or gel type battery backup.
  • Maximum charge current .7 amp.
  • Zero voltage drop upon transfer to battery backup.
  • AC input and DC output LED indicators.
  • AC fail supervision (form "C" contact rated @ 1 amp 28VDC).
  • Low battery and battery presence supervision (form "C" contact rated @ 1 amp 28VDC).
  • Lifetime Warranty.

    Access Power Controller:
  • Eight (8) Access Control System outputs.
    - Eight (8) fuse protected Fail-Safe and/or Fail-Secure 12VDC or 24VDC power outputs.
    - Any power output may be converted to dry form "C" relay output.
    - Eight (8) fuse protected 12VDC or 24VDC auxiliary power outputs (unswitched).
  • Red LEDs indicate outputs are triggered (relays energized). • Eight (8) Access Control System trigger inputs.
    - Eight (8) normally open (NO) inputs.
    - Eight (8) open collector inputs.
    - Any combination of the above.
  • Fire Alarm Disconnect:
    - Fire Alarm Disconnect (latching or non-latching) is individually selectable for any or all of the eight (8) outputs.
    - Normally open (NO) or normally closed (NC) dry contact input.
    - Polarity reversal input FACP signaling circuit.
  • Fire Alarm trigger LED indicates that the Fire Alarm Disconnect has been activated.
  • Fire Alarm output relay for trigering auxiliary reporting devices (form "C" contact rated @ 1 amp 28VDC).
  • Lifetime Warranty.

    Enclosure
  • Accommodates up to two (2) 12VDC/12AH batteries.
  • Dimensions: 15.5”H x 12”W x 4.5”D
  • 1/2 and 3/4 combination knockouts.

    Installation Instructions in PDF format




    AL600ULACM$295.00





  • allkindscable.com is upfront


    Contact Our Sales Dept.

    Comments to: webmaster@allkindscable.com

      

    Coax Cable | Communications & Control Cable | Fire Protection & Signaling Cable | Sound & Audio Cable | LAN Cable | Home Automation Cable | Installation Necessities | Direct Buriel Cable | Power Supplies

    Security Design Services family of companies
    isourcecctv.com | cctvhardware.com | allkindscable.com | securityideas.com
    www.allkindscable.com is TM & copyright 1999-2010 Security Design Services Corp. All promotional art, characters, logos and other depictions are TM & copyright their respective owners. All Rights Reserved.
    XML Product Listing Sitemap XML format

    Site design by Superior Media